    CERTIFIED ENVIRONMENTAL PRODUCT DECLARATION (EPD)

    The Environmental Product Declaration (EPD) is a certified document that provides our clients with reliable, verified, and transparent information regarding the environmental impact throughout the life cycle of a product. This information is based on a Life Cycle Analysis (LCA) study conducted in accordance with the Product Category Rules (PCR) developed by the Eco-labeling Program. In our specific case, the study has been carried out under the Product Category Rule for Construction Products UNE EN 15804:2012+A2. These EPDs can be downloaded by clients directly from AENOR's website. 

    AENOR has bilateral agreements of mutual recognition with key European Program Administrators, including EPD International AB (EIAB) in Sweden, Institut Bauen und Umwelt e.V. (IBU) in Germany, and ICMQ in Italy, which administers the EPD Italy program. This collaboration further enhances the international validity and credibility of our Environmental Product Declarations.

    UL CERTIFICATION

    UL is one of several companies approved by the U.S. Occupational Safety and Health Administration (OSHA) to perform safety testing. More than 50 of our products have obtained their corresponding certifications, thereby making Onyx Solar the leader in safety for photovoltaic glass in the U.S.

    Onyx Solar´s crystalline and amorphous silicon glass panes were investigated by UL succesfully in accordance with the standards for safety UL-1703 & ULC/ORD-C1703 "Standards for Flat-Plate Photovoltaic Modules and Panels". This represented a milestone in the solar industry since no company had been able to certify extra-large and semi-transparent PV glass panes to this standard before.

    IEC CERTIFICATION

    The International Electrotechnical Commission (IEC) is an international organization that prepares and publishes International Standards for all electrical, electronic and related technologies. In the field of photovoltaics, it regulates the manufacture of products and ensures compliance with quality and electrical safety standards.

    All our photovoltaic products comply with IEC61215: 2021 (Terrestrial photovoltaic (PV) modules - Design qualification and type approval) and IEC 61730:2016 (Photovoltaic (PV) module safety qualification) among many others focused on laminated safety glass that apply to BIPV.

    Our products, made of amorphous and crystalline silicon glass (including our Hidden PV glass -coloured-, walkable PV floor tiles, bifacial PV glass modules and more) have passed the most stringent and strictest safety and quality tests. This allows Onyx Solar to continue to offer the highest quality products and to remain a leader in BIPV market.

    These tests include inspections of our manufacturing quality control and production procedures and verification of our test facilities among other requirements.

    No other manufacturer of photovoltaic glass has as many products tested with optimal results.

    IEC 61701 SALT MIST CORROSION TESTING

    Our PV glass panes are certified in accordance with IEC61701, "2nd ed. 2011-12: Salt mist corrosion testing of photovoltaic (PV) modules" and has reached a maximum of 5 in the scale in the severity test.

    FIRE TESTS

    Onyx has successfully tested its fire resistance and reaction according to several industry standards:

    • Our photovoltaic glass is classified as CLASS A material according to UL790 and MST 23 & MST24 in compliance with IEC 61730-2: 2016.
    • ASTM E84.
    • EN 13823: 2010 + A1: 2014 and EN ISO 11925-2: 2010.
    • Fire reaction test according to EN 13501-1: 2007 + A1: 2009.

     

    Additionally, our fire reaction performance meets the highest standards of resistivity, including Australian Standard 1350.3, calorimetric cone tests, TS 1187 tests and EN13501-5.

    Furthermore, our glass products undergo rigorous NFPA 285 testing, assessed alongside their anchoring system in comprehensive evaluations that simulate fire propagation under realistic conditions typical of high-rise buildings. These assessments involve a significant number of units, totaling up to 40, with individual areas exceeding 323 sq ft, incorporating the entire system. This extensive testing has facilitated the integration of our buildings into skyscrapers in the USA and Dubai, complying with the stringent requirements established by Civil Defense for tall structures. For more information, please visit NFPA The National Fire Protection Association.

    SAFETY STANDARDS AS ARCHITECTURAL GLASS

    In order to prove how the product properly meets the most stringent safety standards in construction required for architectural glass, Tecnalia lab has tested our crystalline and amorphous silicon laminated glass in accordance with the requirements set by the UNE-EN 14449:2006 standard: “Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product” . This is a benchmark standard in the field of architectural glass for building integration. All tests performed have turned out to be a great success.

     The glass panes have obtained the best results on the impact resistance tests performed in accordance with UNE-EN 12600:2003 standard.

    The amorphous silicon glass panes have got a P4A rating on the resistance to manual attack tests performed in accordance with UNE-EN 356:2001 standard.

    Resistance to extreme weather conditions was measured by carrying out a test in accordance with UNE-EN ISO 12543-4:2011 standard. The conclusion reached is that the glass panes can still preserve their lamination quality after having kept them exposed under extreme humid conditions.

    Regarding our walkable photovoltaic floor, our product meets the following standards:

    UNE ENV 12633

    Pendulum Method

    Class 3

    DIN 51130

    Ramp Method
    Standard
    Footwear

    R-12

    DIN 51097

    Ramp Method Barefoot

    Class B

    ASTM C 1028-07

    CoF.DRY

    ≥ 0,7

    CoF.WET

    ≥ 0,6

    EN 101:91 MOHS

    Surface hardness

    4-point scale

    Boil and impact test have been performed in accordance with ANSI Z97.1-2015 standard "For safety glazing materials used in buildings - safety performance specifications and methods of test", following the safety performance specifications and testing methods of the American National Standard.

    These certifications enable Onyx to proudly display the CE Marking for both photovoltaic and safety glass materials in buildings. For more information, please visit European Commission - CE marking.

    INTEGRATED MANAGEMENT SYSTEM

    The company has developed an Integrated Management System which has led the company to obtain the corresponding ISO Certifications. Onyx has proved to comply with the requirements of the following two ISO standards: ISO 9001:2005 (Quality Management) and the ISO 14001:2015 (Environmental Management).

    It's also important to highlight that Onyx Solar offers a diverse range of certified products, including XXL glass with active surfaces of up to 47.36 ft sq, weights exceeding 551.16 lb, power up to 660 W, and glazing thickness of up to 24 mm. No other company in the sector has achieved these milestones.

    Additionally, Onyx Solar meets various local certification requirements, including MCS certification for the UK (with over 100 products), CEC in Australia, INMETRO in Brazil, and SHAMS in Dubai.

    SGCC CERTIFICATION

    Onyx Solar is recognized as a manufacturer of safety glass by the American Safety Glass Council (SGCC), a certification held by only a select few European companies. This esteemed recognition underscores our commitment to delivering high-quality photovoltaic solutions that not only enhance energy efficiency but also meeting rigorous safety standards. Our certified safety glass positions Onyx Solar as a market leader, offering unparalleled reliability and safety for building integration. For more information, please visit SGCC.

    CCC CERTIFICATION

    CHINA COMPULSORY PRODUCT CERTIFICATION: Onyx Solar BIPV has met the requirements specified in CNCA-C 3-01:2014 for compulsory certification safety glass products (CCC certification).

    MCS PRODUCT CERTIFICATION

    Quality assurance scheme recognised in the United Kingdom, supported by the Department for Business, Energy & Industrial Strategy. It is managed by the MCS Service Company, a trading subsidiary of the MCS Charitable Foundation. MCS certifies microgeneration technologies used to produce electricity and heat from renewable sources. MCS is also an eligibility requirement for the Government’s financial incentives, which include the Feed-in Tariff and the Renewable Heat Incentive.

    RESISTANCE TESTS

    🌡️

    Temperature Cycling Test (TC200):
    200 cycles of temperature from -40ºC to +85 ºC.

    💧

    Humidity Test (HF10):
    10 cycles of humidity-freezing as 10 cycles of +85 ºC
    following by freezing stage as 85% relative humidity at -40ªC.

    🔅

    Damp Heat test (DHT1000):
    1000 hours at +85 ºC. And 85% relative humidity.

    ⚖️

    Mechanical Loading Test:
    Our system can stand up to a tested load of 5400 Pa (540 kg/m2). The deflection of the system (structure and glass) is below L/240 where L is equal to the clear span length in feet of the deflected member.

    💦

    Light soaking Test:
    Exposure to light cycles from 600 W-1000 W/sqm until the maximum power of the given units stabilized at +/-2%.

    🌨️

    Hail test:
    Ice ball in diameter 25 mm at 23 m/s, directed against 11 points of impact.

    🔥

    Class A on fire safety:
    Highest rating in fire safety standards. Test standard - ASTM E84-16: Standard Test Method for Surface Burning Characteristics of Building materials. Flame Spread index 25; Smoke-developed index 180.

    For more information, check out our Quality and Environmental Policy.

    In conclusion, Onyx Solar has quickly established itself with the largest portfolio of fully tested BIPV products, adhering to prominent global industry standards. This commitment ensures that our products are both reliable and durable, offering an undeniable lifespan, making them suitable for use in any construction market.